Class Overview: A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist HERS Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.
Class Overview:
This 1/2 day class covers Manual ‘J’ Sizing Introduction Manual ‘J’ Wrightsoft Set-up and hands on training Detailed Cooling Capacity Data Sheets Air Flow Calculation Worksheets.
Class Overview:
This 1/2 day class covers Manual S, Sizing of Residential Equipment based on Manual S and the California title 24 Part 6 parameters. Material includes: Reference App JA-II, Various Manufacture Equipment Data sheets, a PowerPoint with a step-by-step work through, and a Wrightsoft Computer element, Other ACCA Approved Software is being brought into the training at this time.
Description:
This full day training class is designed to introduce HVAC Contractors, General Building Contractors, and Mechanical Engineers to the process of duct design and register selection when installing small Commercial HVAC systems. This class includes four specific components. 1. Classroom instruction of the ACCA Duct Design procedure. 2. Classroom instruction on effects of CFM, velocity and pressure on duct desgins and general airflow terminology. 3. Duct sizing practice exercises. 4. Register selection and placement.
Class Overview: Day 4 – Building Envelope I CLASSROOM: Discuss ‘Combustion Analysis’, ‘Room to Room Pressure Diagnostics’ and ‘Duct Leakage Diagnostics’. HANDS ON*: 80 and 95 AFUE Combustion analysis, and Room to Room pressure diagnostics including Duct Leakage Diagnostics, (finding leaks with a manometer).
Objectives: HERS Raters, BPI Contractors, Energy Auditors, Energy Analysts, Architects, Builders and Building Professionals, HVAC Contractors and Technicians, Utility Program Sponsors, Facility and Energy Managers, and Building Officials.
Audience: HERS Raters, BPI Contractors, Energy Auditors, Energy Analysts, Architects, Builders and Building Professionals, HVAC Contractors and Technicians, Utility Program Sponsors, Facility and Energy Managers, and Building Officials.
NATE Certified
Class Overview: A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist HERS Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.
Class Overview: A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist HERS Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.
Class Overview: A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist HERS Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.
Class Overview:
This 1/2 day class covers Manual S, Sizing of Residential Equipment based on Manual S and the California title 24 Part 6 parameters. Material includes: Reference App JA-II, Various Manufacture Equipment Data sheets, a PowerPoint with a step-by-step work through, and a Wrightsoft Computer element, Other ACCA Approved Software is being brought into the training at this time.
This full day training class is designed to introduce HVAC Contractors, General Building Contractors, and Mechanical Engineers to the process of duct design and register selection when installing small Commercial HVAC systems.
This class includes four specific components:
1. Classroom instruction of the ACCA Duct Design procedure.
2. Classroom instruction on effects of CFM, velocity and pressure on duct desgins and general airflow terminology.
3. Duct sizing practice exercises.
4. Register selection and placement.