This 1/2 day class covers Manual S, Sizing of Residential Equipment based on Manual S and the California title 24 Part 6 parameters. Material includes: Reference App JA-II, Various Manufacture Equipment Data sheets, a PowerPoint with a step-by-step work through, and a Wrightsoft Computer element, Other ACCA Approved Software is being brought into the training at this time.
The course covers Basic concepts of duct design. Covers air flow dynamics and static pressures within the systems, defines and explains EL, friction rate, location, throw and spread of grilles, registers and diffusers. Includes a Software portion for Wrightsoft and will include Elite. The information covers efficiencies relating to design, installation as well concepts focusing on delivered efficiencies, operating points, fan and duct curves.
Class Overview:
Day 2 – Building Energy Science
CLASSROOM: Discuss ‘Static Pressure and Airflow, Air Flow Measurement Techniques-Plenum Pressure Matching Method, Flow Hood, Flow Grid.’