Class Schedule

People engaging in conversation on a city street near a bike rack.

Electrification & Home Performance Series: 2 – Moisture & Ventilation (Webinar)

Wednesday 10/15/2025 10:00 AM – 12:00 PM

Non-Invasive Refrigerant Charge Verification of Existing HVAC Systems (Webinar)

Thursday 10/23/2025 9:00 AM – 11:30 AM

Electrification & Home Performance Series: 3 – Air Sealing & Insulation (Webinar)

Wednesday 11/12/2025 10:00 AM – 12:00 PM

Electrification & Home Performance Series: 4 – All About Quality Insulation Installation (QII) (Webinar)

Wednesday 12/3/2025 10:00 AM – 12:00 PM

Electrification & Home Performance Series: 5 – How Tight is Too Tight? (Webinar)

Wednesday 12/17/2025 10:00 AM – 12:00 PM

Electrification & Home Performance Series: 6 – Testing Residential Building Pressure (Webinar)

Thursday 1/15/2026 10:00 AM – 12:00 PM

Electrification & Home Performance Series: 7 – Integrating Heat Pump Water Heaters (Webinar)

Thursday 1/29/2026 10:00 AM – 12:00 PM

Electrification & Home Performance Series: 8 – Water Conservation & Home Performance (Webinar)

Thursday 2/12/2026 10:00 AM – 12:00 PM

Apr
19
Tue
Building Pressure Diagnostics @ SDG&E Energy Innovation Center, San Diego
Apr 19 @ 8:00 am – 12:00 pm

Class Overview:

The House Pressure Diagnostics class explains the principles of air pressure within a building and how to use these principles to diagnose airflow problems. Understanding the principles of airflow within a building can help a HERS Rater locate the largest infiltration leaks and help determine the air leaks that should be addressed first. The training class also demonstrated how to conduct a “duct leakage to outside” test and provides participants the opportunity to perform the test during class.

Reducing air leakage is an important part of nearly all existing home energy improvement programs. And the most important part of understanding and using house pressure diagnostics is that by reducing infiltration cost effectively it helps homeowners achieve energy and cost savings and improves comfort for the homeowner.

Hands-on Refrigerant Charge Measurement @ SDG&E Energy Innovation Center, San Diego
Apr 19 @ 1:00 pm – 5:00 pm

A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist HERS Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.

 

Apr
20
Wed
Equipment Calibration @ SDG&E Energy Innovation Center, San Diego
Apr 20 @ 8:00 am – 12:00 pm

Class Overview: A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.

May
11
Wed
Building Energy Science II – Residential Air Sealing @ SDG&E Energy Innovation Center, San Diego
May 11 @ 8:00 am – 12:00 pm

Class Overview: This training session covers issues and cautions that anyone involved in air sealing needs to consider when tightening a residential structure. It builds upon the principles in Building Energy Science Basics 100. A checklist of inspection points is provided as part of the training.

May
12
Thu
Equipment Calibration @ SDG&E Energy Innovation Center, San Diego
May 12 @ 8:30 am – 12:30 pm

Class Overview: A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.

May
16
Mon
Building Envelope and Duct Testing – MI-BEST Series #1 @ Fresno
May 16 all-day

Search Results

Description:

Building Envelope and Duct Testing Day 1; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 1 is the first of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 1 covers Basic Building Science and Energy Principles, and hands on practice with blower doors and duct testers using the MI-BEST portable training unit.

May
17
Tue
Air Flow Measures and Static Pressure – MI-BEST Series #2 @ Fresno
May 17 all-day

Description:

Air Flow Measures and Static Pressure Day 2; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 2 is the second of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 2 continues the Building Energy Science Theory, focusing on Air flow diagnostics, and building pressures. Introduces HVAC Static Pressure and Airflow, Air Flow Measurement Techniques and devices currently allowed within Title 24, Room to Room pressure diagnostics.
May
18
Wed
Refrigerant Charge Verification – MI-BEST Series #3 @ Fresno
May 18 all-day

Description:

Refrigerant Charge Verification Day 3; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 3 is the third of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 3 covers Building Energy Science focusing on Moisture Issues; Refrigerant Charge Verification and Equipment Calibration. This class combines the air flow techniques covered in Day 2 with refrigerant charge skills. Title 24 requirements are included.
May
19
Thu
Building Pressures and Ventilation Verification – MI-BEST Series #4 @ Fresno
May 19 all-day

Description:

Building Pressures and Ventilation Verification Day 4; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 4 is the fourth of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 4 covers House Ventilation (ASHRAE 62-2 and Title 24) requirements and issues, measuring ventilation flows, and Ventilation Fan effects on building and room pressures.
May
20
Fri
Thermal By-Pass, Quality Insulation Installation, Advanced Building Envelope – MI-BEST Series #5 @ Fresno
May 20 all-day

Description:

Thermal By-pass, Quality Insulation Installation, Advanced Building Enevelope Day 5; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 5 is the last of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 5 covers Thermal Bypass and Quality Insulation Installation, Advanced Framin (OVE), Combustion Analysis, and Thermal Imaging.