Electrification & Home Performance Series: 2 – Moisture & Ventilation (Webinar)
Wednesday 10/15/2025 10:00 AM – 12:00 PM
Non-Invasive Refrigerant Charge Verification of Existing HVAC Systems (Webinar)
Thursday 10/23/2025 9:00 AM – 11:30 AM
Electrification & Home Performance Series: 3 – Air Sealing & Insulation (Webinar)
Wednesday 11/12/2025 10:00 AM – 12:00 PM
Wednesday 12/3/2025 10:00 AM – 12:00 PM
Electrification & Home Performance Series: 5 – How Tight is Too Tight? (Webinar)
Wednesday 12/17/2025 10:00 AM – 12:00 PM
Electrification & Home Performance Series: 6 – Testing Residential Building Pressure (Webinar)
Thursday 1/15/2026 10:00 AM – 12:00 PM
Electrification & Home Performance Series: 7 – Integrating Heat Pump Water Heaters (Webinar)
Thursday 1/29/2026 10:00 AM – 12:00 PM
Electrification & Home Performance Series: 8 – Water Conservation & Home Performance (Webinar)
Thursday 2/12/2026 10:00 AM – 12:00 PM
It is recommended that participants attend this class prior to attending the Advanced ACCA Manual D class. This class provides a review of the ACCA Residential Design System and approved software, Manual D procedure, and proper documentation. Learn how to achieve efficiency compliance while optimizing ductwork for competitive pricing and comfort. North American Technician Excellence (NATE) continuing education credits are available for this class.
It is recommended that participants attend the ACCA Manual J Equipment Sizing and Selection and ACCA Manual D Duct Design courses prior to attending this class. This class will step beyond the introduction to ACCA Manual D to more advanced topics, including how to perform Manual D calculations both manually and using the official Wrightsoft ACCA computer software program.
This class will be presented using computers for hands-on training. Participants will perform group exercises and have the opportunity to work on individual problems with the instructor’s assistance.
Class topics will cover:
– Homes with multiple HVAC systems.
– Two-story homes with single systems.
– Using the computer program to generate room-by-room load calculations and select HVAC equipment.
– How to use the graphic design module of the computer software, which automatically calculates room-by-room load calculations and provides Manual D duct design.
Many homeowners are considering changing ‘Gas Furnaces’ to ‘Heat Pumps’ to provide residential heating and cooling.
The Training builds upon the ACCA Wrightsoft series and focuses on the Science of correct sizing of Heat pump systems and includes a Wrightoft computer lab portion.
The session builds upon Manual ‘J’ and provides a foundation upon which Manual ‘H’ will be built.
It is recommended that attendees bring their own laptop preloaded with the Wrightsoft Demo software
Class Overview:
This four hour session covers the science and application of airflow principles to the efficient operation of HVAC equipment. Many of the residential systems in California suffer from the inefficiencies caused by high static pressure. Included in this training is a hands-on portion designed to compare various filters, fittings and layout issues that cause high static pressures.
Class Overview: A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist HERS Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.
Class Overview:
This 1/2 day class covers Manual ‘J’ Sizing Introduction Manual ‘J’ Wrightsoft Set-up and hands on training Detailed Cooling Capacity Data Sheets Air Flow Calculation Worksheets
Class Overview:
This 1/2 day class covers Manual S, Sizing of Residential Equipment based on Manual S and the California title 24 Part 6 parameters. Material includes: Reference App JA-II, Various Manufacture Equipment Data sheets, a PowerPoint with a step-by-step work through, and a Wrightsoft Computer element, Other ACCA Approved Software is being brought into the training at this time.
The course covers Basic concepts of duct design. Covers air flow dynamics and static pressures within the systems, defines and explains EL, friction rate, location, throw and spread of grilles, registers and diffusers. Includes a Software portion for Wrightsoft and will include Elite. The information covers efficiencies relating to design, installation as well concepts focusing on delivered efficiencies, operating points, fan and duct curves.
Class Overview:
Day 1 – Building Energy Science I
CLASSROOM: Review basic Energy Science and Pressure Diagnostics, Manometer Law and Manometer Usage
HANDS ON: Blower Door, includes four set-up stations and both TEC and Retrotec equipment using multiple manometers. Includes both Pressurization and Depressurization Techniques. Duct Testing Total Leakage and Leakage to Outside Multiple opportunities to set up check the equipment operation procedures.
Class Overview:
Day 2 – Building Energy Science
CLASSROOM: Discuss ‘Static Pressure and Airflow, Air Flow Measurement Techniques-Plenum Pressure Matching Method, Flow Hood, Flow Grid.’
HANDS ON: Measurements-Static Pressure and Airflow, Using The equipment approved in California. Fan watt draw and Airflow using Retrotec and TEC equipment.