Class Schedule

Oct
7
Fri
Thermal By-Pass, Quality Insulation Installation, Advanced Building Envelope – MI-BEST Series #5 @ PG & E Energy Training Center, Stockton
Oct 7 all-day

Description:

Thermal By-pass, Quality Insulation Installation, Advanced Building Enevelope Day 5; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 5 is the last of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 5 covers Thermal Bypass and Quality Insulation Installation, Advanced Framin (OVE), Combustion Analysis, and Thermal Imaging.
Nov
28
Mon
Building Envelope and Duct Testing – MI-BEST Series #1 @ PG & E Energy Training Center
Nov 28 all-day

Description:

Building Envelope and Duct Testing Day 1; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 1 is the first of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 1 covers Basic Building Science and Energy Principles, and hands on practice with blower doors and duct testers using the MI-BEST portable training unit.

Nov
29
Tue
Air Flow Measures and Static Pressure – MI-BEST Series #2 @ PG & E Energy Training Center
Nov 29 all-day

Description:

Air Flow Measures and Static Pressure Day 2; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 2 is the second of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 2 continues the Building Energy Science Theory, focusing on Air flow diagnostics, and building pressures. Introduces HVAC Static Pressure and Airflow, Air Flow Measurement Techniques and devices currently allowed within Title 24, Room to Room pressure diagnostics.
Nov
30
Wed
Refrigerant Charge Verification – MI-BEST Series #3 @ PG & E Energy Training Center
Nov 30 all-day

Description:

Refrigerant Charge Verification Day 3; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 3 is the third of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 3 covers Building Energy Science focusing on Moisture Issues; Refrigerant Charge Verification and Equipment Calibration. This class combines the air flow techniques covered in Day 2 with refrigerant charge skills. Title 24 requirements are included.
Dec
1
Thu
Building Pressures and Ventilation Verification – MI-BEST Series #4 @ PG&E Energy Training Center
Dec 1 all-day

Description:

Building Pressures and Ventilation Verification Day 4; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 4 is the fourth of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 4 covers House Ventilation (ASHRAE 62-2 and Title 24) requirements and issues, measuring ventilation flows, and Ventilation Fan effects on building and room pressures.
Dec
2
Fri
Thermal By-Pass, Quality Insulation Installation, Advanced Building Envelope – MI-BEST Series #5 @ PG&E Energy Training Center, Stockton
Dec 2 all-day

Description:

Thermal By-pass, Quality Insulation Installation, Advanced Building Enevelope Day 5; Building Energy Science, Building Performance Made Practical; MI-BEST® (Mobile Integrated Building Energy Science Training) Day 5 is the last of 5 consecutive days of training which are designed to be covered in sequence. Students are encouraged to stay for the entire 5 days, but may sign up for individual days depending on the agenda. Day 5 covers Thermal Bypass and Quality Insulation Installation, Advanced Framin (OVE), Combustion Analysis, and Thermal Imaging.
Jan
19
Thu
Hands-on Refrigerant Charge Measurement @ SCE Energy Education Center, Irwindale
Jan 19 @ 1:00 pm – 5:00 pm

Class Overview: A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist HERS Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.

Feb
7
Tue
Hands-on Refrigerant Charge Measurement @ SDG&E Energy Innovation Center, San Diego
Feb 7 @ 8:00 am – 12:00 pm

Class Overview: A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist HERS Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.

Feb
21
Tue
Hands-on Refrigerant Charge Measurement @ SCE Energy Education Center, Irwindale
Feb 21 @ 1:00 pm – 5:00 pm

Class Overview: A residential split system air conditioner undergoes its final assembly at the time of installation. An important factor is the amount of refrigerant in the system (commonly referred to as proper charging). Air conditioner energy efficiency suffers if the refrigerant charge is either too low or too high. This training is designed to assist HERS Raters and HVAC technicians to properly perform a Refrigerant Charge verification. This is a Hands-on class with operational equipment. Please feel free to bring your verification equipment.

Feb
23
Thu
ACCA Manual D @ SCE Energy Education Center, Irwindale
Feb 23 all-day

The course covers Basic concepts of duct design. Covers air flow dynamics and static pressures within the systems, defines and explains EL, friction rate, location, throw and spread of grilles, registers and diffusers. Includes a Software portion for Wrightsoft and will include Elite. The information covers efficiencies relating to design, installation as well concepts focusing on delivered efficiencies, operating points, fan and duct curves.